=== Do not change lines below ===
{
"chain": [],
"cmd": "heudiconv --subjects f --files sourcedata/phantom-mri-dicom-frankfurt/G000a__MRT2_20250416_1549_Phan20250416__20250416_171402035 --outdir . --heuristic code/heuristic-q01.py --converter dcm2niix --bids --minmeta --overwrite",
"dsid": "698cec3c-e424-47e0-9da4-7a75e5ed6078",
"exit": 0,
"extra_inputs": [],
"inputs": [
"sourcedata/phantom-mri-dicom-frankfurt/G000a__MRT2_20250416_1549_Phan20250416__20250416_171402035"
],
"outputs": [],
"pwd": "."
}
^^^ Do not change lines above ^^^
86 lines
3.3 KiB
JSON
86 lines
3.3 KiB
JSON
{
|
|
"AcquisitionDuration": 65.147,
|
|
"AcquisitionMatrixPE": 140,
|
|
"AcquisitionNumber": 1,
|
|
"AcquisitionTime": "17:14:39.357500",
|
|
"BandwidthPerPixelPhaseEncode": 21.978,
|
|
"BaseResolution": 140,
|
|
"BidsGuess": [
|
|
"dwi",
|
|
"_acq-epse2p2m2_dir-PA_run-26_dwi"
|
|
],
|
|
"BodyPartExamined": "BRAIN",
|
|
"CoilCombinationMethod": "Sum of Squares",
|
|
"CoilString": "HeadNeck_20",
|
|
"ConversionSoftware": "dcm2niix",
|
|
"ConversionSoftwareVersion": "v1.0.20240202",
|
|
"DerivedVendorReportedEchoSpacing": 0.000650001,
|
|
"DeviceSerialNumber": "166335",
|
|
"DiffusionScheme": "Monopolar",
|
|
"DwellTime": 1.9e-06,
|
|
"EchoTime": 0.07,
|
|
"EchoTrainLength": 52,
|
|
"EffectiveEchoSpacing": 0.000325,
|
|
"FlipAngle": 90,
|
|
"FrequencyEncodingSteps": 140,
|
|
"HeudiconvVersion": "1.3.3",
|
|
"ImageOrientationPatientDICOM": [0.999999, 0.000993556, 0.000358867, -0.00104719, 0.977059, 0.212966],
|
|
"ImageType": [
|
|
"ORIGINAL",
|
|
"PRIMARY",
|
|
"DIFFUSION",
|
|
"NONE"
|
|
],
|
|
"ImageTypeText": [
|
|
"ORIGINAL",
|
|
"PRIMARY",
|
|
"DIFFUSION",
|
|
"NONE",
|
|
"ND"
|
|
],
|
|
"ImagingFrequency": 123.255469,
|
|
"InPlanePhaseEncodingDirectionDICOM": "COL",
|
|
"InstitutionAddress": "Heinrich-Hoffmann-Str. 9,Frankfurt am Main,Hessen,DE,60528",
|
|
"InstitutionName": "Goethe Universit\u00e4t",
|
|
"InstitutionalDepartmentName": "CoBIC",
|
|
"MRAcquisitionType": "2D",
|
|
"MTState": false,
|
|
"MagneticFieldStrength": 3,
|
|
"Manufacturer": "Siemens",
|
|
"ManufacturersModelName": "MAGNETOM Prisma",
|
|
"Modality": "MR",
|
|
"MultibandAccelerationFactor": 2,
|
|
"NonlinearGradientCorrection": false,
|
|
"ParallelAcquisitionTechnique": "SMS",
|
|
"ParallelReductionFactorInPlane": 2,
|
|
"PartialFourier": 0.75,
|
|
"PartialFourierDirection": "PHASE",
|
|
"PatientPosition": "HFS",
|
|
"PercentPhaseFOV": 100,
|
|
"PercentSampling": 100,
|
|
"PhaseEncodingDirection": "j",
|
|
"PhaseEncodingSteps": 140,
|
|
"PhaseResolution": 1,
|
|
"PixelBandwidth": 1880,
|
|
"ProcedureStepDescription": "Setup_protocols 4Ecker",
|
|
"ProtocolName": "Q01_dwi_acq-mshell-1p5refb0ref",
|
|
"PulseSequenceDetails": "%SiemensSeq%\\ep2d_diff",
|
|
"PulseSequenceName": "*epse2d1_140",
|
|
"ReceiveCoilActiveElements": "HE1-4;NE1,2",
|
|
"ReceiveCoilName": "HeadNeck_20",
|
|
"ReconMatrixPE": 140,
|
|
"RefLinesPE": 24,
|
|
"RepetitionTime": 6.3,
|
|
"ScanOptions": "PFP\\FS",
|
|
"ScanningSequence": "EP",
|
|
"SequenceVariant": "SK\\SP",
|
|
"SeriesDescription": "Q01_dwi_acq-mshell-1p5refb0ref",
|
|
"SeriesNumber": 26,
|
|
"ShimSetting": [-1712, -4311, -3139, 127, -49, -125, 25, 39],
|
|
"SliceThickness": 1.5,
|
|
"SliceTiming": [4.71, 0, 3.14, 0.1325, 3.27, 0.2625, 3.4025, 0.3925, 3.5325, 0.525, 3.6625, 0.655, 3.795, 0.785, 3.925, 0.9175, 4.055, 1.0475, 4.1875, 1.1775, 4.3175, 1.31, 4.4475, 1.44, 4.58, 1.7025, 4.84, 1.8325, 4.9725, 1.9625, 5.1025, 2.095, 5.2325, 2.225, 5.365, 2.355, 5.495, 2.4875, 5.625, 2.6175, 5.7575, 2.7475, 5.8875, 2.88, 6.0175, 3.01, 6.15, 1.57, 4.71, 0, 3.14, 0.1325, 3.27, 0.2625, 3.4025, 0.3925, 3.5325, 0.525, 3.6625, 0.655, 3.795, 0.785, 3.925, 0.9175, 4.055, 1.0475, 4.1875, 1.1775, 4.3175, 1.31, 4.4475, 1.44, 4.58, 1.7025, 4.84, 1.8325, 4.9725, 1.9625, 5.1025, 2.095, 5.2325, 2.225, 5.365, 2.355, 5.495, 2.4875, 5.625, 2.6175, 5.7575, 2.7475, 5.8875, 2.88, 6.0175, 3.01, 6.15, 1.57],
|
|
"SoftwareVersions": "syngo MR XA60",
|
|
"SpacingBetweenSlices": 1.5,
|
|
"StationName": "AWP166335",
|
|
"TotalReadoutTime": 0.045175,
|
|
"TxRefAmp": 292.387} |