phantom-mri-bids/sub-m/anat/sub-m_T1w.json
Michał Szczepanik bb760f73e9 [DATALAD RUNCMD] Convert the Mannheim phantom data to BIDS
=== Do not change lines below ===
{
 "chain": [],
 "cmd": "heudiconv --subjects m --files sourcedata/phantom-mri-dicom-mannheim/TRR379_Q01_phantom_TRR379_Q01_phantom_20000101/TRR379_Q01_20250319_134541.800000 --outdir . --heuristic code/heuristic-q01.py --converter dcm2niix --bids --minmeta --overwrite",
 "dsid": "698cec3c-e424-47e0-9da4-7a75e5ed6078",
 "exit": 0,
 "extra_inputs": [],
 "inputs": [
  "sourcedata/phantom-mri-dicom-mannheim/TRR379_Q01_phantom_TRR379_Q01_phantom_20000101/TRR379_Q01_20250319_134541.800000"
 ],
 "outputs": [],
 "pwd": "."
}
^^^ Do not change lines above ^^^
2025-05-16 22:23:23 +02:00

77 lines
2.2 KiB
JSON

{
"AcquisitionDuration": 395.522,
"AcquisitionMatrixPE": 300,
"AcquisitionNumber": 1,
"AcquisitionTime": "13:49:10.710000",
"BaseResolution": 320,
"BidsGuess": [
"anat",
"_acq-tfl3p2_run-5_T1w"
],
"BodyPartExamined": "BRAIN",
"CoilCombinationMethod": "Adaptive Combine",
"CoilString": "HeadNeck_20",
"ConversionSoftware": "dcm2niix",
"ConversionSoftwareVersion": "v1.0.20240202",
"DeviceSerialNumber": "167069",
"DwellTime": 7.1e-06,
"EchoTime": 0.00222,
"FlipAngle": 8,
"FrequencyEncodingSteps": 320,
"HeudiconvVersion": "1.3.3",
"ImageOrientationPatientDICOM": [-0.00446354, 0.977883, 0.209106, -0.00192275, 0.2091, -0.977892],
"ImageType": [
"ORIGINAL",
"PRIMARY",
"M",
"NONE"
],
"ImageTypeText": [
"ORIGINAL",
"PRIMARY",
"M",
"NORM",
"DIS2D"
],
"ImagingFrequency": 123.259318,
"InPlanePhaseEncodingDirectionDICOM": "ROW",
"InstitutionAddress": "J 5,Mannheim,District,DE,68159",
"InstitutionName": "Zentralinstitut fuer seelische Gesundheit",
"InversionTime": 1.03,
"MRAcquisitionType": "3D",
"MTState": false,
"MagneticFieldStrength": 3,
"Manufacturer": "Siemens",
"ManufacturersModelName": "MAGNETOM Prisma Fit",
"MatrixCoilMode": "GRAPPA",
"Modality": "MR",
"NonlinearGradientCorrection": true,
"ParallelAcquisitionTechnique": "GRAPPA",
"ParallelReductionFactorInPlane": 2,
"PartialFourier": 1,
"PatientPosition": "HFS",
"PercentPhaseFOV": 93.75,
"PercentSampling": 100,
"PhaseEncodingSteps": 300,
"PhaseEncodingStepsOutOfPlane": 208,
"PhaseResolution": 1,
"PixelBandwidth": 220,
"ProcedureStepDescription": "TRR379 Q01",
"ProtocolName": "Q01_anat_acq-0p8mm_T1w",
"PulseSequenceDetails": "%SiemensSeq%\\tfl",
"PulseSequenceName": "*tfl3d1_256ns",
"ReceiveCoilActiveElements": "HE1-4;NE1,2",
"ReceiveCoilName": "HeadNeck_20",
"ReconMatrixPE": 300,
"RefLinesPE": 32,
"RepetitionTime": 2.4,
"ScanOptions": "IR\\WE",
"ScanningSequence": "GR\\IR",
"SequenceVariant": "SK\\SP\\MP",
"SeriesDescription": "Q01_anat_acq-0p8mm_T1w",
"SeriesNumber": 5,
"ShimSetting": [-4285, -11491, 4812, -310, 0, -15, -1, 2],
"SliceThickness": 0.8,
"SoftwareVersions": "syngo MR XA60",
"StationName": "MRC35396",
"TxRefAmp": 289.535}