phantom-mri-bids/sub-m/dwi/sub-m_acq-mshell_sbref.json
Michał Szczepanik bb760f73e9 [DATALAD RUNCMD] Convert the Mannheim phantom data to BIDS
=== Do not change lines below ===
{
 "chain": [],
 "cmd": "heudiconv --subjects m --files sourcedata/phantom-mri-dicom-mannheim/TRR379_Q01_phantom_TRR379_Q01_phantom_20000101/TRR379_Q01_20250319_134541.800000 --outdir . --heuristic code/heuristic-q01.py --converter dcm2niix --bids --minmeta --overwrite",
 "dsid": "698cec3c-e424-47e0-9da4-7a75e5ed6078",
 "exit": 0,
 "extra_inputs": [],
 "inputs": [
  "sourcedata/phantom-mri-dicom-mannheim/TRR379_Q01_phantom_TRR379_Q01_phantom_20000101/TRR379_Q01_20250319_134541.800000"
 ],
 "outputs": [],
 "pwd": "."
}
^^^ Do not change lines above ^^^
2025-05-16 22:23:23 +02:00

85 lines
3.2 KiB
JSON

{
"AcquisitionDuration": 65.15,
"AcquisitionMatrixPE": 140,
"AcquisitionNumber": 1,
"AcquisitionTime": "14:34:14.417500",
"BandwidthPerPixelPhaseEncode": 21.978,
"BaseResolution": 140,
"BidsGuess": [
"dwi",
"_acq-epse2p2m2_dir-PA_run-24_dwi"
],
"BodyPartExamined": "BRAIN",
"CoilCombinationMethod": "Sum of Squares",
"CoilString": "HeadNeck_20",
"ConversionSoftware": "dcm2niix",
"ConversionSoftwareVersion": "v1.0.20240202",
"DerivedVendorReportedEchoSpacing": 0.000650001,
"DeviceSerialNumber": "167069",
"DiffusionScheme": "Monopolar",
"DwellTime": 1.9e-06,
"EchoTime": 0.07,
"EchoTrainLength": 52,
"EffectiveEchoSpacing": 0.000325,
"FlipAngle": 90,
"FrequencyEncodingSteps": 140,
"HeudiconvVersion": "1.3.3",
"ImageOrientationPatientDICOM": [0.999988, 0.00483974, -0.000931327, -0.00453788, 0.977869, 0.209168],
"ImageType": [
"ORIGINAL",
"PRIMARY",
"DIFFUSION",
"NONE"
],
"ImageTypeText": [
"ORIGINAL",
"PRIMARY",
"DIFFUSION",
"NONE",
"ND"
],
"ImagingFrequency": 123.25936,
"InPlanePhaseEncodingDirectionDICOM": "COL",
"InstitutionAddress": "J 5,Mannheim,District,DE,68159",
"InstitutionName": "Zentralinstitut fuer seelische Gesundheit",
"MRAcquisitionType": "2D",
"MTState": false,
"MagneticFieldStrength": 3,
"Manufacturer": "Siemens",
"ManufacturersModelName": "MAGNETOM Prisma Fit",
"Modality": "MR",
"MultibandAccelerationFactor": 2,
"NonlinearGradientCorrection": false,
"ParallelAcquisitionTechnique": "SMS",
"ParallelReductionFactorInPlane": 2,
"PartialFourier": 0.75,
"PartialFourierDirection": "PHASE",
"PatientPosition": "HFS",
"PercentPhaseFOV": 100,
"PercentSampling": 100,
"PhaseEncodingDirection": "j",
"PhaseEncodingSteps": 140,
"PhaseResolution": 1,
"PixelBandwidth": 1880,
"ProcedureStepDescription": "TRR379 Q01",
"ProtocolName": "Q01_dwi_acq-mshell-1p5refb0ref",
"PulseSequenceDetails": "%SiemensSeq%\\ep2d_diff",
"PulseSequenceName": "*epse2d1_140",
"ReceiveCoilActiveElements": "HE1-4;NE1,2",
"ReceiveCoilName": "HeadNeck_20",
"ReconMatrixPE": 140,
"RefLinesPE": 24,
"RepetitionTime": 6.3,
"ScanOptions": "PFP\\FS",
"ScanningSequence": "EP",
"SequenceVariant": "SK\\SP",
"SeriesDescription": "Q01_dwi_acq-mshell-1p5refb0ref",
"SeriesNumber": 24,
"ShimSetting": [-4280, -11483, 4846, -455, 9, -59, 36, -6],
"SliceThickness": 1.5,
"SliceTiming": [4.71, 0, 3.14, 0.13, 3.27, 0.26, 3.4, 0.3925, 3.5325, 0.5225, 3.6625, 0.6525, 3.7925, 0.785, 3.925, 0.915, 4.055, 1.045, 4.185, 1.1775, 4.3175, 1.3075, 4.4475, 1.4375, 4.5775, 1.7, 4.84, 1.83, 4.97, 1.9625, 5.1025, 2.0925, 5.2325, 2.2225, 5.3625, 2.355, 5.495, 2.485, 5.625, 2.615, 5.755, 2.7475, 5.8875, 2.8775, 6.0175, 3.0075, 6.1475, 1.57, 4.71, 0, 3.14, 0.13, 3.27, 0.26, 3.4, 0.3925, 3.5325, 0.5225, 3.6625, 0.6525, 3.7925, 0.785, 3.925, 0.915, 4.055, 1.045, 4.185, 1.1775, 4.3175, 1.3075, 4.4475, 1.4375, 4.5775, 1.7, 4.84, 1.83, 4.97, 1.9625, 5.1025, 2.0925, 5.2325, 2.2225, 5.3625, 2.355, 5.495, 2.485, 5.625, 2.615, 5.755, 2.7475, 5.8875, 2.8775, 6.0175, 3.0075, 6.1475, 1.57],
"SoftwareVersions": "syngo MR XA60",
"SpacingBetweenSlices": 1.5,
"StationName": "MRC35396",
"TotalReadoutTime": 0.045175,
"TxRefAmp": 289.535}